Chapter 4 - Maintenance
75
Running the Cleaning Cartridge
This procedure assumes that the cleaning cartridge has been installed into Slot 1 of the
system.
1.
On the control panel of the Global Control Module, at the Default Screen, press the
Enter
button. The display will show the following.
Figure 4-1
Main Menu
2.
Press the
θ
button twice to move the next to ‘Maintenance Menu’, then press the
Enter
button to select the Maintenance Menu. The display will show something
similar to the following.
Figure 4-2
Maintenance Menu
3.
Press the
Enter
button once to select Clean Drive., The following screen appears.
Figure 4-3
Cleaning Submenu
4.
Lines 2 and 4 are scrollable. The choices available on Line 2 are DLT1 through
DLTn. Let us assume you want to clean DLT1. Press the
Enter
button once to
accept DLT1. The
moves to line 4 of the display. Press the
Enter
button again to
use the cartridge in Slot 1. Note: If you are unable to use slot 1 for the cleaning
cartridge, you can scroll line 4 to select another slot.
5.
The Clean Confirmation Screen appears, as shown below.
Load/Unload
Show Status Menu
Maintenance Menu
Configuration Menu
Clean Drive
Diagnostic Menu
Demo Menu
Flash Update
Cleaning:
✱
✱
DLT1
Using
✱
✱
Slot1
Summary of Contents for DLT LibraryXpress Series
Page 8: ......
Page 20: ......
Page 52: ......
Page 80: ......
Page 92: ......
Page 130: ......
Page 134: ...126 Appendix A Specifications...
Page 135: ...Appendix A Specifications 127 a p a c i t y C C a pa city C C...
Page 136: ...128 Appendix A Specifications...
Page 138: ......
Page 140: ......