30
Chapter 2 - Installation
Control Cables
Connect each slave module to the Global Control Module using one of the cables with a DB-9
male connector at the slave end and a DB-9 female at the Global Control Module end. A cable
is required for each slave module. Note: Any of the control cables may be connected to any of
the DB-9 connectors on the back panel of the Global Control Module. The Global Control
Module determines the location of each module during power-up tests.
Power Cord
The detachable AC power cord is a standard grounding AC cord which attaches to an IEC-
compatible connector on the rear panel. Connect a cord to the connector on each module, and
connect the other end to a reliably grounded AC outlet or rack power outlet.
To maintain safety compliance, use a power cord with a suitable rating that is approved for
the country in which the product is used. In the US cords must be UL listed, in Canada, CSA
certified, and in Europe use a Harmonized cord marked <HAR> or a nationally certified cord.
SCSI Interfaces
DLT LibraryXpress Modules may be ordered with a choice of single-ended or differential
SCSI-2 interfaces, or, if 7000 series drives are used, single-ended or differential Fast/Wide
SCSI. Both SCSI-2 interfaces use two parallel female high-density 50-pin D-series connectors
per bus. SCSI-2 cables and terminators are secured to the connectors by spring-loaded
latches. Fast/Wide SCSI is available only as differential, and uses two parallel female high-
density 68-pin D-Series connectors per bus. Fast/Wide SCSI cables and terminators are
secured to the connectors by jackscrews.
Note: The internal wiring length of any rack-mounted SCSI system can approach the
maximum length specification of a single-ended SCSI bus. The maximum length specification
for a differential SCSI bus is four times longer. Overland Data strongly recommends that you
use differential controllers and high-quality SCSI cables to ensure the highest performance of
your LibraryXpress. Bus errors caused by excessive length or poor quality cables can
significantly degrade performance and reliability.
Summary of Contents for DLT LibraryXpress Series
Page 8: ......
Page 20: ......
Page 52: ......
Page 80: ......
Page 92: ......
Page 130: ......
Page 134: ...126 Appendix A Specifications...
Page 135: ...Appendix A Specifications 127 a p a c i t y C C a pa city C C...
Page 136: ...128 Appendix A Specifications...
Page 138: ......
Page 140: ......