4-2
Section
Key Settings
46
4-2-7
Initialization (
reset
)
The following procedure can be used to clear all set values and
return to the default values.
Procedure
1
Set the operating mode switch to RUN.
2
Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.
3
Press the Up Key to go to the initialization.
scale
oUt
hys
hold
reset
baUp
bank
Measurement
width
Discrimination
outputs
Hysteresis
setting
Hold
Initialization
Backup
Bank selection
4
Press the SET Key.
All the settings will be cleared and reset to default values.
5
Press the TEACH Key to return to RUN mode.
Default Settings
Item
Default setting
Meaning
Measurement width
10
10 mm
Discrimination
outputs
hĆl1
HIGH/LOW output
Hysteresis setting
0.020
0.020 V
y
g
00.050
0.050 mm
Hold
norml
Normal
Bank selection
off
Disabled
Backup
on
Enabled
HIGH threshold
4.000
4.000 V
07.500
7.500 mm
LOW threshold
2.000
2.000 V
02.500
2.500 mm