![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323083.webp)
7-1
Section
Specifications
60
7-1
Specifications
7-1-1
Standard Sensors (Separate Type)
Sensors
Item
Z4LB-S10V2
Z4LB-S30V2
Light source
Visible-light semiconductor laser (Wavelength: 650 nm,
IEC Class 1, FDA Class II)
Measurement width
10 mm
30 mm
Sensing distance
0 to 300 mm
Minimum sensing object
0.1 mm dia.
0.2 mm dia.
Linear output
Temperature characteristic: 0.1% F.S./
°
C (see notes 1 and
2)
Ambient operating
illumination
3,000 lx max. (incandescent lamp)
Ambient temperature
Operating: 0 to 50
°
C
Storage:
–15 to 60
°
C (with no icing)
Ambient humidity
Operating: 35% to 85% (with no condensation)
Storage:
35% to 85% (with no condensation)
Vibration resistance
10 to 150 Hz, half-amplitude of 0.75 mm, acceleration of
100 m/s
2
max.
Dielectric strength
1,000 VAC 50/60 Hz 1 min
Degree of protection
IEC60529 IP40
Cable
Cable with connector (standard length: 2 m)
Material
Zinc die-cast
Weight (in package)
310 g
790 g
Accessories
Two mounting brackets
Four, 25-mm M3 screws
Four, M3 nuts
Five labels
Two mounting brackets
Six, 25-mm M4 screws
Five labels
Note
1 “F.S.” stands for full scale. In the case of the Z4LB-S10V2,
for example, the F.S. value is 10 mm.
2 The temperature characteristic value for the linear output is
a typical value on condition that a single sensor is applied to
measurement.