![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323065.webp)
4-2
Section
Key Settings
42
Default setting: The hysteresis is set to 0.020 when the
measurement unit is V, to 00.050 when the measurement
unit is mm and the measurement width is 10 mm, and to
00.150 when the measurement unit is mm and the measure-
ment width is 30 mm.
Setting Range
Measured value
di
l
it
Measurement width of the Sensor
display unit
10 mm
30 mm
V
0.002 to 0.800
mm
0.005 to 2.000
0.015 to 6.000
0
0.050
00.0
5
0
00.0
6
0
The selected digit flashes.
Select the digit.
Set the value.
6
Press the SET Key.
The set value will be entered and the Sensor will return to
function selection mode.
7
Press the TEACH Key to return to RUN mode.
4-2-4
Display/Output Value Hold (
hold
)
There are six methods to hold the display and output values. Se-
lect the best method for the application.
Display
Name
Description
Page
norml
Normal
The result of measurement is always
displayed and output. The hold does not
work.
50
pĆh
Peak hold
The maximum value while the timing input is
ON is displayed, output, and held.
51
bĆh
Bottom hold
The minimum value while the timing input is
ON is displayed, output, and held.
52
sĆh
Sample hold
The current value when the timing input turns
ON is displayed, output, and held.
53
ppĆh
Peak-to-peak
hold
The difference between the maximum and
minimum values while timing input is ON is
displayed, output, and held.
54
spĆh
Self-peak hold
The maximum value while the measured
value is equal to or greater than the trigger
level is displayed, output, and held.
55
sbĆh
Self-bottom hold
The minimum value while the measured
value is equal to or less than the trigger level
is displayed, output, and held.
56