![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323044.webp)
!
2-5
Section
Sensor Installation
19
2
Closely attach the emitter and the receiver with the name-
plates of both the emitter and the receiver facing the same
direction.
3
Use the provided screwdriver and turn the gain adjuster so
that the display on the Amplifier reads 5.000
±
0.1 V.
Turn clockwise
or counterclock-
wise
4
Mount the emitter and the receiver in the desired position.
Secure the receiver and tentatively secure the emitter.
5
Change the angle of the emitter upwards, downwards, left,
and right with no sensing object and secure the position of
the emitter at the angle where the maximum value is dis-
played.
6
Turn the gain adjuster so that the display reads
5.000
±
0.005 V.
2-5
Sensor Installation
2-5-1
Sensors
Caution
Do not touch the optical filter of a Sensor. If it is stained with finger
prints or other material, measurements may not be performed
correctly. If you touch the filter by mistake, clean it with a soft
cloth.