3-2
Section
Setting Thresholds
29
3-2-2
Teaching Thresholds
HIGH indicator
Display
LOW indicator
HIGH Threshold Setting
1
Set the operating mode selector to H.
The display will show the present HIGH threshold and the
HIGH indicator will flash. If the bank selection is enabled, the
bank number will be displayed.
→
Refer to
4-2-5 Enabling the Bank Selection (p. 44)
.
2
Set the workpiece and press the TEACH Key.
Teaching will be performed. The HIGH threshold obtained
from the teaching value plus an approximate value of 0.7%
F.S. will be displayed.
HIGH threshold
Teaching value of reference workpiece
Fine Adjustment of Values
The thresholds after teaching are reference values that can
be changed to desired values. Go to step 3 to change the
thresholds, otherwise go to step 5.