![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323061.webp)
4-2
Section
Key Settings
38
4-2
Key Settings
4-2-1
Setting the Measurement Width (
scale
)
The following settings are required only if the Z4LB-S30V2 Sen-
sor is to be used with the measurement unit set to mm.
The following steps make it possible to change the measure-
ment width. For details, refer to
3-1 Selecting the Measurement
Unit
.
→
Refer to
Z4LB-S30V2 Sensor
under
3-1 Selecting the Mea-
surement Unit (p. 24).
Procedure
There are two procedures that can be used to set thresholds. Se-
lect the easier method according to the application. The following
example shows how to set the measurement width in function
selection mode.
1
Set the operating mode selector to RUN.
2
Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.
3
Press the Up Key to go to measurement width setting.
scale
Measurement width
4
Press the SET Key.
5
Press the UP Key twice to change 1 to 3.
1
0
2
0
3
0
The figure
1
flashes.
6
Press the SET Key.
The set value will be entered and the display will flash twice.
7
Press the TEACH Key to return to RUN mode.