4-2
Section
Key Settings
40
3
Press the Up Key to go to the discrimination outputs.
scale
oUt
Measurement width
Discrimination outputs
4
Press the SET Key.
The discrimination outputs can now be selected.
5
Press the Up Key and select the discrimination outputs.
hĆl1
pass
hĆl2
HIGH/LOW output
PASS/NG output
HIGH/LOW
inverted output
6
Press the SET Key
The discrimination outputs will be entered and the Sensor
will return to function selection mode.
7
Press the TEACH Key to return to RUN mode.
4-2-3
Hysteresis Setting (
hys
)
The hysteresis can be set to provide a margin in making discrimi-
nation outputs.
Discrimination Outputs Timing Charts
HIGH/LOW Output Mode
ON
OFF
ON
OFF
HIGH threshold
Hysteresis
Measured value
LOW threshold
HIGH output
LOW output