![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323086.webp)
7-1
Section
Specifications
63
Item
Z4LB-A3040V2
Z4LB-A1040V2
Vibration
resistance
Sensor
10 to 150 Hz, half-amplitude of 0.75 mm, acceleration of
100 m/s
2
max.
Amplifier
10 to 150 Hz, half-amplitude of 0.15 mm acceleration of
20 m/s
2
max.
Dielectric
t
th
Sensor
1,000 VAC 50/60 Hz 1 min
strength
Amplifier
300 VAC 50/60 Hz 1 min
Degree of protection
IEC60529 IP40
Connection method
Connector (Standard sensor cable length; 2 m, Standard
amp cable length; 2 m)
Material
Sensor: Diecast zinc, Amplifier: ABS
Weight (including package)
610 g
900 g
Attachments
Instruction manual, 5 labels
Note
1 The resolution is the peak-to-peak displacement conver-
sion value for the linear output.
2 The typical value measured with only a Sensor and an
Amplifier.
3 Linearity: The value deviated from the ideal straight line
measured at the center point between Emitter and Receiver
with 5% to 95% F.S. one-side light interruption. For the
Z4LB-A1040V2 or Z4LB-A1040PV2, the range is from 0.5
to 9.5 mm.