![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323068.webp)
4-2
Section
Key Settings
45
4-2-6
Enabling Backup (
baUp
)
Determine whether the forced-zero value is to be backed up or
not, i.e., to hold the value after the Sensor is turned OFF. If the
backup is not enabled, the value will be lost when the Sensor is
turned OFF.
Note
If the backup is enabled, the forced-zero value will be written to
the internal EEPROM, which is a nonvolatile. The EEPROM has
a limit on the number of writing times. Therefore, if the forced-
zero value is changed frequently, disable the backup to increase
the life of the memory.
Procedure
1
Set the operating mode selector to RUN.
2
Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.
3
Press the Up Key to go to the backup.
scale
oUt
hys
hold
baUp
bank
Measurement
width
Discrimination
outputs
Hysteresis
setting
Hold
Backup
Bank selection
4
Press the SET Key.
The backup can now be set.
5
Press the Up Key to enable or disable the backup.
on
off
Enabled
Disabled
6
Press the SET Key
The backup will be entered and the Sensor will return to
function selection mode.
7
Press the TEACH Key to return to RUN mode.