![background image](http://html.mh-extra.com/html/omron/z4lb-v2/z4lb-v2_instruction-manual_1633323049.webp)
3-1
Section
Selecting the Measurement Unit
25
Checking and Changing the Measurement Width
Display
1
Set the operating mode selector to RUN.
2
Press the TEACH and SET Keys simultaneously for 3 s.
The present measurement width will be displayed.
(The default setting is 10.)
3
Press the Up Key twice and change the value from 1 to 3.
1
0
2
0
3
0
The value
1
flashes.
Press the Up Key.
Press the Up Key.
4
Press the SET Key.
The set value will be entered and the indicator will flash
twice.