Selector Settings
48
Dark Mode
Example
Emitter
Receiver
Rod diameter
inspection
Emitter
Receiver
Sensing object
The output is proportional to
the amount of blocked light.
Linear output (V)
Display in mm
Blocked light
* “F.S.” stands for full scale. In
the case of the Z4LB-S10V2,
for example, the F.S. value is
10 mm.
*
4-3-2
Response Time Selection
The resolution changes with the response time. Select the re-
quiring response time, taking the resolution into consideration.
Selection
Response
ti
Resolution
p
time
Z4LB-S10V2
Z4LB-A1040V2
Z4LB-A1040PV2
Z4LB-S30V2
Z4LB-A3040V2
Z4LB-A3040PV2
SLOW
5 ms
5
µ
m
15
µ
m
FAST
0.3 ms
10
µ
m
30
µ
m
4-3-3
OFF Delay
The discrimination outputs will have a 40-ms OFF delay if the
OFF delay selector is set to ON.