![background image](http://html.mh-extra.com/html/omron/sysmac-cvm1-pro01-v1/sysmac-cvm1-pro01-v1_operation-manual_742440025.webp)
1-5
Section
Precautions When Using the CV500-MC221
12
1-5
Precautions When Using the CV500-MC221
The operating procedures of the Teaching Box using the CS1W-MC421 MC Unit
or the CS1W-MC221 MC Unit are respectively the same as those of the Teach-
ing Box using the CV500-MC421 MC Unit or the CV500-MC221 MC Unit.
Descriptions in this manual are given for the Teaching Box using the CS1W-
MC421 or the CV500-MC421. Note the following precautions when using the
CV500-MC221.
Item
Precautions
Monitoring
Monitored current data is displayed for all four axes. “0” is
displayed for the unsupported axes (Z and U axes).
The I/O signals are also displayed for all four axes. The
CCW limit input, CW limit input, emergency stop input and
alarm input are displayed as “1” for unsupported axes as
shown below. (Even when “1” is displayed, the X and Y
axis can be operated.)
*
: “0” or “1”
MON| XYZU
IN |ORIG POS**00
|CCW LIMT**11
|CW LIMIT**11
MON| XYZU
IN |DRV ALRM**11
|STOP **11
|
Jog MPG
The +Z, –Z, +U and –U Keys are not supported.
Other functions
All other operations for the Z and U axes are also not
supported.