3-5 Regeneration Resistance Unit
3-5-1 Regeneration Resistance Unit (R88A-RG08UA) Specifications
3-5 Regeneration Resistance Unit
3-5-1
Regeneration Resistance Unit (R88A-RG08UA) Specifications
General Specifications
Item
Specifications
Ambient operating temperature
0 to 55
°
C
Ambient operating humidity
35% to 85% (with no condensation)
Ambient storage temperature
−
10 to 75
°
C
Ambient storage humidity
35% to 85% (with no condensation)
Storage and operating
atmosphere
No corrosive gasses
Vibration resistance
4.9 m/s
2
max.
Impact resistance
Acceleration 19.6 m/s
2
max.
Characteristics
Item
Specifications
Regeneration operating voltage
380 VDC
Regeneration current
8 A (DC)
Average internal regeneration power
12 W (internal resistance: 50
Ω
, 60 W)
Externally connected regeneration
resistance
47
Ω
±
5%
Error detection functions
Regeneration resistance disconnection, Regeneration transistor
failure, and overvoltage
Alarm output
Single-pole NC contact (open when protection function is
operating), can handle 200 VAC.
Dimensions
55
×
160
×
130 mm (W
×
H
×
D)
LED Indicator Specifications
Item
Specifications
POWER
Lit when power is being supplied to the P and N terminals.
REGEN
Lit during regeneration operation.
ALARM-REGEN
Lit when the regeneration resistance is disconnected or the regeneration
transistor failed.
ALARM-OV
Lit when there is an overvoltage.
Note 1. If an error is detected, an alarm is output from the Regeneration Resistance Unit. Set up
a sequence so that the power to the Servo Driver (L1 and L2) is turned OFF when an
alarm occurs.
2. When an error is detected and the Servo Driver’s power is turned OFF, the Regeneration
Resistance Unit will not reset normally unless the Servo Driver’s power is OFF for 2 to 3
seconds. (The Regeneration Resistance Unit will reset to its normal status after the
Servo Driver’s internal capacitors discharge completely and the voltage drops across
terminals P and N.)
3. The Regeneration Resistance Unit does not comply with the EC Directives.
3-24
Summary of Contents for SMARTSTEP Junior R7D-ZP
Page 3: ...2 ...
Page 18: ...Section 1 Configuration Features and System ...
Page 25: ...1 5 Applicable Standards 1 5 2 UL and cUL Standards 1 8 ...
Page 26: ...Section 2 Dimensions Standard Models and ...
Page 36: ...Section 3 Specifications ...
Page 62: ...Section 4 System Design ...
Page 86: ...Section 5 Operation ...
Page 96: ...Section 6 Troubleshooting ...
Page 109: ...6 5 Periodic Maintenance 6 5 3 Replacing the Cooling Fan 6 14 ...
Page 110: ...Appendix ...