A-1 Connection Examples
Example 3: Connecting to a SYSMAC CJ1M PLC
CJ1M R7D-ZP
@
R7A-CPZ
@
S
R7M-Z
@
Note 1. Incorrect signal wiring can
cause damage to Units and
the Servo Driver.
2. Leave unused signal lines
open and do not wire them.
3.
Use mode 2 for origin
search.
4.
Use a dedicated power
supply as the 24-V DC
power supply for command
pulse signals.
5.
The
diode
recommended
for surge absorption is the
ERB44-02 (Fuji Electric).
6. Do not use the 24-VDC
control power supply for the
brake power supply (24
VDC).
Signal
Main circuit power supply
Main circuit contact
Surge suppressor
Servo error indicator
3-phase 200/230 VAC, 50/60Hz
Ground to 100
Ω
or less.
Noi
s
e f
ilt
er
Input for the output power supply
Output COM
Pulse
output 0
CW output
CCW output
Deviation counter reset output
Origin input signal
Positioning completed signal
Origin proximity input signal
R7A-CRZ
@
C
Encoder Cable
R7A-CAZ
@
S
R7A-CAZ
@
B
Servomotor Power Cable
Connect an external
Regeneration Resistance Unit
when required.
Red
White
Blue
Green/
Yellow
Linear reactor
Fuse
Shell
Example 4: Connecting to a SYSMAC CP1H-Y20DT-D PLC
Output terminal block
CP1H-Y20DT-D R7D-ZP
@
R7A-CPZ
@
S
R7M-Z
@
Note 1. Incorrect signal wiring can
cause damage to Units and
the Servo Driver.
2. Leave unused signal lines
open and do not wire them.
3. The diode recommended
for surge absorption is the
ERB44-02 (Fuji Electric).
4. Do not use the 24-VDC
control power supply for the
brake power supply (24
VDC).
Main circuit power supply
Main circuit contact
Surge suppressor
Servo error indicator
3-phase 200/230 VAC, 50/60Hz
Ground to 100
Ω
or less.
Noi
s
e f
ilt
er
Pulse
output 0
Origin search 0 (CIO 0101.02)
24-VDC input terminal (+)
24-VDC input terminal (–)
COM (CIO 0101)
Input terminal block
Pulse 0 origin input signal (CIO 0000.00)
COM (CIO 0000)
Pulse 0 origin proximity input signal (CIO 0000.01)
R7A-CRZ
@
C
Encoder Cable
R7A-CAZ
@
S
R7A-CAZ
@
B
Servomotor Power Cable
Connect an external
Regeneration Resistance Unit
when required.
Red
White
Blue
Green/
Yellow
Linear reactor
Fuse
Shell
CCW0
−
A-3
Summary of Contents for SMARTSTEP Junior R7D-ZP
Page 3: ...2 ...
Page 18: ...Section 1 Configuration Features and System ...
Page 25: ...1 5 Applicable Standards 1 5 2 UL and cUL Standards 1 8 ...
Page 26: ...Section 2 Dimensions Standard Models and ...
Page 36: ...Section 3 Specifications ...
Page 62: ...Section 4 System Design ...
Page 86: ...Section 5 Operation ...
Page 96: ...Section 6 Troubleshooting ...
Page 109: ...6 5 Periodic Maintenance 6 5 3 Replacing the Cooling Fan 6 14 ...
Page 110: ...Appendix ...