![background image](http://html1.mh-extra.com/html/omron/smartstep-2-r7d-bp01h/smartstep-2-r7d-bp01h_user-manual_741362150.webp)
4-5
4-1 Installation Conditions
4
System Design
Oil Seal
The Servomotor oil seal dimensions are given below. The expected service life of an oil seal is
approximately 5,000 hours. The actual life depends on the application conditions and environment.
Oil seal installation and replacement are treated as repair work. For inquiries, consult your OMRON
representative.
When using the Servomotor in an environment where the Servomotor shaft will be exposed to oil,
select a Servomotor with an oil seal.
Precautions
Keep the oil level below the oil seal.
The Oil Seal is made of rubber and may burn if it is used in an environment where it is subjected
to no oil at all. Always use the Servomotor in an environment with a suitable amount of oil.
Install the Servomotor so that oil does not accumulate around the oil seal.
Other Precautions
Take measures to protect the shaft from corrosion.
The shafts are coated with anti-corrosion oil when shipped, but anti-corrosion oil should be
removed when connecting the shaft to a load.
Motor model
Shaft
diameter (mm)
Outer diameter
(mm)
Width
(mm)
R88M-G05030L/H
8.9
17
4
R88M-G10030L/H
8.9
17
4
R88M-G20030L/H
14
28
4
R88M-G40030H
14
28
4
R88M-GP10030L/H
8.9
22
4
R88M-GP20030L/H
14
28
4
R88M-GP40030H
14
28
4
W
AR
N
I
N
G
Do not apply commercial po
w
er directly to the Ser
v
omotor.
Doing so may res
u
lt in fire.
Do not dismantle or repair the prod
u
ct.
Doing so may res
u
lt in electric shock or inj
u
ry.