4-7
4-1 Installation Conditions
4
System Design
Installing the Decelerator
When installing the R88G-HPG
@
, first make sure that the mounting surface is flat and that there are
no burrs on the tap sections, and then bolt on the mounting flanges.
Mounting Flange Bolt Tightening Torque for Aluminum
Decelerator model
Number of
bolts
Bolt size
Mounting PCD
(mm)
Tightening torque
(N·m)
R88G-HPG11
@
4
M3
46
1.4
R88G-HPG14
@
4
M5
70
6.3
R88G-HPG20
@
4
M8
105
26.1
R88G-HPG32
@
4
M10
135
51.5