3-7
CHAPTER 3 Installation
4
Exhaust Port
The dust/drip proof models have 6 air exhaust ports (12mm dia.) in the
base (pedestal) rear panel. These provide an air passage for extending and
retracting the Z-axis bellows. If these exhaust ports are blocked, the bellows
cannot adequately extend or retract and may be damaged.
Plugs are inserted in these exhaust ports before shipment so always be sure to
remove them before operating the robot.
If moisture or dust is entering from these exhaust ports, connect them to a
12mm diameter air tube extending to a location free of dust and moisture.
WARNING
TURN OFF POWER TO THE CONTROLLER BEFORE DOING PIPING OR
TUBING WORK.
CAUTION
BEFORE OPERATING THE ROBOT, ALWAYS BE SURE TO REMOVE THE
PLUG INSTALLED IN THE EXHAUST PORT PRIOR TO SHIPPING. IF NOT
REMOVED, THE BELLOWS WILL BE UNABLE TO EXTEND AND
RETRACT AND MAY BE DAMAGED.
WARNING
INSTALL THE EXHAUST TUBING SO THEY WILL NOT BECOME AN
OBSTRUCTION THAT MIGHT CAUSE INJURIES IF PEOPLE STUMBLE
ON IT AND FALL.
CAUTION
INSTALL THE EXHAUST TUBING SO THEY WILL NOT OBSTRUCT
ROBOT MOVEMENT.