668
Compatibility with Screen Data of Other PT Models
APPENDIX I
Differences between the NT30/NT30C and the NT31/NT31C
The differences on scren creation and programming between the NT30/NT30C and the NT31/NT31C are indicated
below. Here, the explanation is subjected to the NT31/NT31C with “V1”. For details of the differences between the
NT31/NT31C without “V1” and the NT31/NT31C with “V1”, refer to “Differences between the NT31/NT31C without
“V1” and the NT31/NT31C with “V1” (page 672). For details of the difference in function, refer to 1-2 “Functions of
the NT31/NT31C” (page 4).
Item
NT30/NT30C
NT31/NT31C
Foreground/
background
relationships
in screen
drawing
Display
Element Type
Contents of display elements that have data
System keypad
Frames of broken line graphs
Frames of trend graphs
Input settings
(numeral, character string, thumbwheel, temporary)
Frames of bar graphs
Fixed displays
Lamps (normal lamp frames)
Alarm list/history frames
Touch switches
Image/library data
Screen background
Foreground
Background
Display
Element Type
Image/library lamps
Alarm list/history frames
Temporary input
Character string input
Thumbwheel type input
Numeral input
Trend graphs
Broken line graphs
Analogue meter
Frames of bar graphs
Numeral displays
Character string displays
Fixed displays
Lamp displays
Touch switches
Image/library
Screen background
Foreground
Background
PT status
control area
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word n
Word n+1
Word n+2
Word n+3
Screen number (4 BCD digits)
Copy type
PT status control bits
0
0
0
Copy source memory table number (3 BCD digits)
Copy destination memory table number (3 BCD digits)
Bit
Word
Word n+4
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word n
Word n+1
Word n+2
Word n+3
Bit
Word
Screen number (4 BCD or hexadecimal digits)
Copy source memory table number (4 BCD or hexadecimal digits)
Copy destination memory table number (4 BCD or hexadecimal digits)
PT status control bits
Reserved for system use
PT status control bits
Word
Controlled Item
1 (ON)
0 (OFF)
15
Screen display
Performed
Not performed
14
Processing priority registration
Registered
Canceled
13
Continuous buzzer
Sounded
Stopped
12
Intermittent buzzer (short)
Sounded
Stopped
11
Display history initialization
Performed
Not performed
10
Not used
Always “0”
9
Intermittent buzzer (long)
Sounded
Stopped
8
Not used
Always “0”
7
Screen printing
Performed
Not performed
6
Window opening
Disabled
Enabled
5
Numeral/character string input
Disabled
Enabled
Reflected in word unit
PT status control bits
Word
Controlled Item
1 (ON)
0 (OFF)
15
Screen display
Performed
Not performed
14
Processing priority registration
Registered
Canceled
13
Continuous buzzer
Sounded
Stopped
12
Intermittent buzzer (short)
Sounded
Stopped
11
Display history initialization
Performed
Not performed
10
Not used
Always “0”
9
Intermittent buzzer (long)
Sounded
Stopped
8
Backlight mode
Lit
Flashing
7
Screen printing
Performed
Not performed
6
PT window opening
Disabled
Enabled
5
Numeral/character string input
Disabled
Enabled
4
PT screen switching
Disabled
Enabled
3
Memory table copy execution Performed
Not performed
2
Memory table copy type
Numeral
Character string
1
Alarm history initialization
Performed
Not performed
0
Not used
Always “0”
Reflected in bit unit
Summary of Contents for NT31 Series
Page 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Page 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Page 41: ...30 Before Operating Section 1 5...
Page 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Page 160: ...149...
Page 174: ...163...
Page 193: ...182...
Page 211: ...200...
Page 235: ...224 c Return to the screen on which screens are specified...
Page 262: ...251...
Page 360: ...349 It is not possible to control a gloval window by touch switch operation...
Page 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Page 476: ...465 Special Functions Section 7 16...
Page 495: ...484 OFF...
Page 610: ...599 Commands Responses Section 9 3...
Page 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...