373
Graphs
Section 7-10
[Common Attributes]
The relationship between the properties of a bar graph and the display results is
indicated below.
S
Properties
General
Position
Coordinates of the top left corner of the bar graph area.
Size
Width and height of the area in which the bar graph is displayed
(dot units)
Width: 2 to 230 Height: 2 to 240
Frame
Whether or not a frame is displayed for the graph area
Check mark (frame displayed)/
No check mark (frame not displayed)
Display Sign
Whether or not a negative area is displayed.
Check mark (displayed)/No check mark (not displayed)
Direction
Direction in which the bar graph extends (“Incremental Direction of
Bar Graphs”, page 375)
Up/Down/Left/Right
Color
Frame
Display color of the frame (colors other than black and white fea-
tured with NT31C only)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
+ Range
Display color of the positive range (colors other than black and
white featured with NT31C only)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
−
Range
Display color of the negative range (colors other than black and
white featured with NT31C only) (effective only when a check
mark is set for “Display Sign”)
Black/Blue/Red/Magenta/Green/Cyan/Yellow/White
Settings
Value
Table Entry
Number of numeral memory table whose contents are to be dis-
played.
Display %
Presence/absence of a percentage indication of the contents of
the numeral memory table (“Method for calculating the percentage
value”, page 375)
Check mark (percentage displayed)/
No check mark (no percentage display)
For details on the “Display %” property, refer to 7-4-2 “Text (Fixed
Display)” (page 310).
*2
100%
*1
(Specify 100% value using either of “Table Entry” or “Value”.)
Table Entry
Numeral memory table number checked to find the 100% value
for percentage calculations
Designate the number of the numeral memory table that
stores the 100% value.
Range: 0 to 1999
Value
Checked to find the 100% value for percentage calculations
Designate the 100% value (default: 100)
Range:
−
2147483648 to 2147483647
Reference
- It is not possible to specify a character attribute and transparent background for
a percentage display.
- It is possible to specify a double width font type for a percentage display.
Summary of Contents for NT31 Series
Page 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Page 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Page 41: ...30 Before Operating Section 1 5...
Page 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Page 160: ...149...
Page 174: ...163...
Page 193: ...182...
Page 211: ...200...
Page 235: ...224 c Return to the screen on which screens are specified...
Page 262: ...251...
Page 360: ...349 It is not possible to control a gloval window by touch switch operation...
Page 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Page 476: ...465 Special Functions Section 7 16...
Page 495: ...484 OFF...
Page 610: ...599 Commands Responses Section 9 3...
Page 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...