223
System Maintenance
Section 6-11
6-11-6
Checking Screen Data
The NT31/NT31C allows the registered screens (Nos. 1 to 3999) to be displayed
and checked by operation from the System Menu.
Reference
- Window screens cannot be displayed by operation from the System Menu.
- Only the user screens (Nos. 1 to 3999) can be displayed. Screens for system
use cannot be displayed.
S
Specifying the display method
Specify the display method for the screens as indicated in the table below.
Setting Item
Function
Setting
Options
Display of Lamp/
Touch SW No.
Allows designation of whether the bit number of the lamp bit set for a lamp or touch
switch is displayed or not.
The display format is as follows “L
jfffffff
” (
j
: area type,
fffffff
: bit
number).
ON, OFF*
Display of Memory
Table No.
Allows designation of whether the table numbers of numeral and character string
memory tables are displayed or not.
The display format for numeral memory tables is “N
ffff
” and the display format for
character string memory tables is “S
ffff
”.
This function is valid for the following display elements.
- Numeral displays
- Character string displays
- Bar graphs
- Numeral setting input fields (including thumbwheel type)
- Character string input fields
ON, OFF*
Display of image/
Library No.
Allows designation of whether image/library code numbers are displayed or not.
ON, OFF*
Display of Broken
Line Frame
Allows designation of whether or not broken line frames are displayed around the display
elements for showing the positions registered.
ON, OFF*
*
Default (factory) setting
Reference: Each setting of the screen data check is effective only on this menu. Exiting from
this screen data check menu resets the settings to the default (all the settings are
set to “OFF”).
S
Operations on the “SCREEN DATA CHECK” screen
The function shown below can be set on the “SCREEN DATA CHECK” screen.
Use this function as required when displaying complex screens on which multi-
ple display elements have been registered overlapping each other.
a) Equivalent to 2 touch switches (14.4 mm)
c)
b) Equivalent to 2 touch switches (14.4 mm)
a) Display the previous display element on the upper most portion of the screen
in the order in which the display elements were registered (excluding fixed
display elements).
b) Display the next display element on the upper most portion of the screen in
the order in which the display elements were registered (excluding fixed dis-
play elements).
Summary of Contents for NT31 Series
Page 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Page 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Page 41: ...30 Before Operating Section 1 5...
Page 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Page 160: ...149...
Page 174: ...163...
Page 193: ...182...
Page 211: ...200...
Page 235: ...224 c Return to the screen on which screens are specified...
Page 262: ...251...
Page 360: ...349 It is not possible to control a gloval window by touch switch operation...
Page 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Page 476: ...465 Special Functions Section 7 16...
Page 495: ...484 OFF...
Page 610: ...599 Commands Responses Section 9 3...
Page 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...