669
Compatibility with Screen Data of Other PT Models
APPENDIX I
Item
NT30/NT30C
NT31/NT31C
PT status
notify area
Bit
Screen number (4 BCD digits)
Numeral/character string memory table number
(3 BCD digits)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word m
Word m+1
Word m+2
Word
0
0
0
0
PT status notify bits
0
PT status notify bits
0
0
0
Bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word m
Word m+1
Word
Numeral/character string memory table number
(BCD or hexadecimal 4 digits)
PT status notify bits
Word
Notified Information
1 (ON)
0 (OFF)
15
PT operation status
Run
Stop
14
Not used
Always “0”
13
Battery
Low
Normal
12
Screen switch strobe
ON
OFF
11
Numeral setting strobe
ON
OFF
10
Character string setting strobe
ON
OFF
9
Not used
Always “0”
8
Not used
Always “0”
7
Printer operating status
Printing
Stopped
PT status notify bits
Word
Notified Information
1 (ON)
0 (OFF)
15
PT operation status
Run
Stop
14
Not used
Always “0”
13
Battery
Low
Normal
12
Screen switch strobe
ON
OFF
11
Numeral setting strobe
ON
OFF
10
Character string setting strobe
ON
OFF
9
Not used
Always “0”
8
Not used
Always “0”
7
Printer operating status
Printing
Stopped
6
Backlight status
OFF
Lit/flashing
5*
Global window open status
Open
Close
4*
Local window “1” open status Open
Close
3*
Local window “2” open status Open
Close
* : Added for V1
The contents of Screen number of the displayed screen (PT status
notify area mCH of NT30/NT30C) is written to PT status control area
nCH.
Window
control area
None
Word k+1
Bit
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Word k
Word
Global window
Screen No. (4-digit BCD or hexadecimal)
Global window
X coordinate (4-digit BCD or hexadecimal)
Global window
Y coordinate (4-digit BCD or hexadecimal)
Local window1
X coordinate (4-digit BCD or hexadecimal)
Local window1
Y coordinate (4-digit BCD or hexadecimal)
Local window1
Screen No. (4-digit BCD or hexadecimal)
Local window2
X coordinate (4-digit BCD or hexadecimal)
Local window2
Y coordinate (4-digit BCD or hexadecimal)
Local window2
Screen No. (4-digit BCD or hexadecimal)
Word k+2
Word k+3
Word k+4
Word k+5
Word k+6
Word k+7
Word k+8
Screen
display
0:
No display
1 to 1899:
Normal screens
1900 to 1979: Window screens, normal screens
1980 to 1996: Expansion functions, normal screens
1997:
Display history (occurrence order) screen
1998:
Display history (frequency order) screen
1999:
“Connected to host” screen
0:
No display
1 to 3999 :
Normal screens, window screens, overlapping screens
9000:
“System Initializing” screen
9001:
Display history (occurrence order) screen
9002:
Display history (frequency order) screen
9020:
Screen for programming console function
9999:
Return to the previous screen
Continuous
screens
Possible
Not possible
A parent screen is deleted after the data conversion, such as from
NT30/NT30C.
Use aswitch screen touch switch instead.
Initial screen
“Host connect” screen
“System initializing” screen
System
keypad
Possible
Not possible
Use touch switches instead.
Also, symbol manager can be used at the Support Tool.
Summary of Contents for NT31 Series
Page 1: ...Cat No V043 E1 2 Programmable Terminal NT31 31C OPERATION MANUAL...
Page 2: ...iii NT31 31C Programmable Terminal Operation Manual Produced March 1999...
Page 41: ...30 Before Operating Section 1 5...
Page 75: ...64 Using a Memory Unit NT31 NT31C without V1 Section 3 6...
Page 160: ...149...
Page 174: ...163...
Page 193: ...182...
Page 211: ...200...
Page 235: ...224 c Return to the screen on which screens are specified...
Page 262: ...251...
Page 360: ...349 It is not possible to control a gloval window by touch switch operation...
Page 468: ...457 254 255 0 2 7 1 4 5 3 3 0 0 0 5 9 8 0 3...
Page 476: ...465 Special Functions Section 7 16...
Page 495: ...484 OFF...
Page 610: ...599 Commands Responses Section 9 3...
Page 630: ...619 Examples of Actual Applications of Memory Link Section 10 2...