MicroHAWK Engine Integration Guide
15-5
Output Format
Format Extract
Output Index
Start Location
Length
Definition:
Output Index
refers to the database entry you wish to modify with this command.
A formatted output is built by
extracting data from a symbol’s original data
output
and/or inserting user-defined characters.
It may be helpful to think of individual indexes as positions in the final formatted
output you wish to build. Starting with index # 1, enter either an extract or
insert command to begin building your desired output string. Then, with the
next index number, enter either an extract or insert command to continue
building the output string. Continue this process until you are finished building
the string.
Serial Cmd:
<
K740,
output index
,start location,length>
Options:
1 to 100
Definition:
Defines the location within the symbol data where the character extraction will
begin. The first character extracted will also be the first character in the
sequence displayed in user-defined output.
Serial Cmd:
<
K740,
output index,
start location
,length>
Default:
0
Options:
1 to
n
(maximum number of characters in the symbol data).
Definition:
Defines the length (in consecutive characters) that will be extracted and
placed in user-defined output.
Serial Cmd:
<
K740,
output index,start location,
length
>
Default:
0
(disabled; end of format cell array)
Options:
1 to
n
(maximum number of characters in the symbol data).
Summary of Contents for MicroHAWK
Page 1: ...MicroHAWK Engine Integration Guide P N 84 9007100 02 Rev B...
Page 74: ...2 18 MicroHAWK Engine Integration Guide Send Receive Options...
Page 78: ...3 4 MicroHAWK Engine Integration Guide Optical Requirements Optical Requirements Base Side...
Page 79: ...MicroHAWK Engine Integration Guide 3 5 Integration Viewing Port Specifications...
Page 80: ...3 6 MicroHAWK Engine Integration Guide Expansion Connector FPC Expansion Connector FPC...
Page 101: ...MicroHAWK Engine Integration Guide 4 21 Communications Keyboard Languages...
Page 102: ...4 22 MicroHAWK Engine Integration Guide USB HID Keyboard Keyboard Languages continued...
Page 103: ...MicroHAWK Engine Integration Guide 4 23 Communications Keyboard Languages continued...
Page 108: ...4 28 MicroHAWK Engine Integration Guide Entering ASCII Characters as Hex Values...
Page 120: ...5 12 MicroHAWK Engine Integration Guide Additional Notes about Calibration...
Page 148: ...6 28 MicroHAWK Engine Integration Guide Minimum Good Reads...
Page 188: ...7 40 MicroHAWK Engine Integration Guide DotCode...
Page 238: ...8 50 MicroHAWK Engine Integration Guide Image Push to Host Detailed Setup...
Page 268: ...10 14 MicroHAWK Engine Integration Guide New Master Pin...
Page 296: ...11 28 MicroHAWK Engine Integration Guide Set License...
Page 314: ...12 18 MicroHAWK Engine Integration Guide Request All Configuration Database Settings...