Appendices
Specifications
A-3
■
Characteristics
K3HB-R
Display range
−
19,999 to 99,999
Measurement accuracy
(at 23±5
°
C)
Functions F1, F6:
±0.006% rdg ±1 digit (for voltage pulse/open collector sensors)
Functions F2 to F5: ±0.02% rdg ±1 digit (for voltage pulse/open collector sensors)
Measurement range
Functions F1 to F6: 0.5 mHz to 50 kHz (for voltage pulse/open-collector sensors)
Input signals
No-voltage contact
(30-Hz max. with ON/OFF pulse width of 15 ms min.)
Voltage pulse
(50-KHz max. with ON/OFF pulse width of 9 µs min.; ON voltage: 4.5 to 30 V;
OFF voltage:
−
30 to 2 V; input impedance: 10 k
Ω
)
Open collector
(50-KHz max. with ON/OFF pulse width of 9 µs min.)
Connectable sensors
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current:
Must have a switching capacity of 20 mA or higher.
Must be able to properly switch load currents of 5 mA or less.
Comparative output re-
sponse time (transistor
output)
Functions F1 to F6: 100 ms max. (time until the comparative output is made when there is a forced
sudden change in the input signal from 15% to 95% or 95% to 15%.)
Linear output response
time
Functions F1 to F6: 110 ms max. (time until the final analog output value is reached when there is a
forced sudden change in the input signal from 15% to 95% or 95% to 15%.)
Insulation resistance
20 M
Ω
min. (at 500 VDC)
Dielectric strength
2,300 VAC for 1 min between external terminals and case
Noise immunity
100 to 240 VAC models:
±
1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1
µ
s/100 ns)
24 VAC/VDC models:
±
1,500 V at power supply terminals in normal or common mode
(waveform with 1-ns rising edge and pulse width of 1
µ
s/100 ns)
Vibration resistance
Frequency: 10 to 55 Hz; Acceleration: 50 m/s
2
, 10 sweeps of 5 min each in X, Y, and Z directions
Shock resistance
150 m/s
2
(100 m/s
2
for relay outputs) 3 times each in 3 axes, 6 directions
Weight
Approx. 300 g (Base Unit only)
Degree of
protection
Front panel
Conforms to NEMA 4X for indoor use (equivalent to IP66)
Rear case
IP20
Terminals
IP00 + finger protection (VDE0106/100)
Memory protection
EEPROM (non-volatile memory)
Number of rewrites: 100,000
Applicable standards
UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMC
EMI: A1 industrial applications
Electromagnetic radiation interference
CISPR 11 Group 1, Class A: CISPRL16-1/-2
Terminal interference voltage
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EMS: A1 industrial applications
Electrostatic Discharge Immunity
EN61000-4-2: 4 kV (contact), 8 kV (in air)
Radiated Electromagnetic Field Immunity
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4 to 2 GHz)
Electrical Fast Transient/Burst Immunity
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
Surge Immunity
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
Conducted Disturbance Immunity
EN61000-4-6: 3 V (0.15 to 80 MHz)
Power Frequency Magnetic Immunity
EN61000-4-8: 30 A/m (50 Hz) continuous time
Voltage Dips and Interruptions Immunity
EN61000-4-11: 0.5 cycle, 0
°
/180
°,
100% (rated voltage)
Summary of Contents for K35-2
Page 2: ......
Page 24: ...Outline Section 1 Outline 1 8 ...
Page 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Page 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...
Page 62: ...Initial Setup Section 4 Initial Setup 4 8 ...
Page 148: ...Functions and Operations Section 5 Functions and Operations 5 86 ...
Page 149: ...6 1 Troubleshooting Section 6 Troubleshooting 6 1 Error Displays 6 2 6 2 Countermeasures 6 3 ...
Page 152: ...Troubleshooting Section 6 Troubleshooting 6 4 ...
Page 185: ......