Functions and Oper
ations
Section 5 Functions and Operations
5-8
Parameter Setting Procedure
A
Press the
M
[MODE] Key several times to display the
comparative set value to be changed.
• One of the values between HH and LL will flash, according to
the displayed comparative set value.
B
Press the
S
[SHIFT] Key to make the SV display flash.
• The setting can be changed when the SV display starts to
flash.
C
Use the
S
[SHIFT] Key and
U
[UP] Key to change the
comparative set value.
D
Press the
M
[MODE] Key to switch to the next parameter.
• The comparative set value set in step C is registered.
123.4
:9999
M
123.4
:9999
L
S
123.4
123.0
L
U
123.4
:9999
LL
M