Functions and Oper
ations
Section 5 Functions and Operations
5-34
5.8
Not Performing Measurements for Set Intervals
With this function measurement is not performed until a set time has
passed after the S-TMR input turns ON. (Timing starts at the rising
edge of the S-TMR input and the PV display is “
-----
” while no
measurement has been performed.)
If the power is turned ON while the
s-tmr
input is ON, measurement
will not start until the time set in the
s-tmr
elapses.
This can be used to create a waiting status until a rotating body
reaches its normal speed range when the power to the K3HB and the
rotating body is turned ON at the same time.
Use the following parameter to set the time.
Parameter Setting Procedure
Advanced function setting level
Parameter
Set value
Meaning of set value
Startup compensation timer
s-tmr
0.
0
Startup compensation timer disabled
0.
.1
to
99.
9
0.1 to 99.9 s
R
s-tmr
L
f
(S-TMR)
3 s min.
A
Press the
L
[LEVEL] Key for at least 3 s in RUN level to move to
the initial setting level.
• “
L
0
” is displayed on the level/bank display to indicate the initial
setting level.
B
Press the
M
[MODE] Key several times to change the PV display
to “
amov
.”
• This parameter is not displayed for the initial status due to setting
level protect.
Refer to "5.34 Limiting Key Operations" (P.5-84) for information on
removing setting level protect.
C
Press the
S
[SHIFT] Key to make the SV display flash.
• The setting can be changed when the SV display starts to
flash.
D
Use the
U
[UP] and
S
[SHIFT] Keys to set the password “
-
0169
.” Press the
M
[MODE] Key to move to the advanced
function setting level.
• “
L
f
” is displayed on the level/bank display to indicate the
advanced function setting level.
E
Press the
M
[MODE] Key several times to change the PV display
to “
s-tmr
.”
F
Press the
S
[SHIFT] Key to make the SV display flash.
• The setting can be changed when the SV display starts to
flash.
Displays “L
0
.”
L
0
L
amov
0
L
0
M
amov
00000
L
0
S
init
Displays “L
f
.”
off
L
f
U
M
s-tmr
0.
0
L
f
M
s-tmr
00.
0
L
f
S
Summary of Contents for K35-2
Page 2: ......
Page 24: ...Outline Section 1 Outline 1 8 ...
Page 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Page 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...