Functions and Oper
ations
Knowledge Required for Setting Parameters
5-5
Procedure
The Setting Level Protect setting must be set to 0 (
set.pt
=
0
) to
enable moving to the advanced function setting level.
Refer to "5.34 Limiting Key Operations" (P.5-84) for the procedure to
release protection.
• The advanced function setting level will be entered if the password
is correct.
• If the password is incorrect, the first parameter on the initial setting
level will be displayed.
A
Move to the initial setting level, press the
M
[MODE] Key several
times to display the “
amov
” (move to advanced function setting
level) parameter.
B
Press the
S
[SHIFT] Key to enable entering the password.
C
Use the
S
[SHIFT] and
U
[UP] Keys to set the password.
The password is “
-0169
” (-0169).
D
Press the
M
[MODE] Key to write the password.
init
off
f
amoV
0016
9
0
amoV
0
0
Move to the advanced function setting level.
The set value is always 0 after moving
from character display to monitor status.
(Does not move to the advanced function setting level.)
To next parameter
Advanced function setting level
Set value initialization
Password doesn't match.
Password matches.
Change status
Use the
S
[SHIFT]
and
U
[UP] Keys
to set the password.
Summary of Contents for K35-2
Page 2: ......
Page 24: ...Outline Section 1 Outline 1 8 ...
Page 25: ...2 1 Preparations Section 2 Preparations 2 1 Mounting 2 2 2 2 Using I O 2 4 ...
Page 54: ...Basic Application Methods Basic Application Methods Section 3 Basic Application Methods 3 18 ...
Page 62: ...Initial Setup Section 4 Initial Setup 4 8 ...
Page 148: ...Functions and Operations Section 5 Functions and Operations 5 86 ...
Page 149: ...6 1 Troubleshooting Section 6 Troubleshooting 6 1 Error Displays 6 2 6 2 Countermeasures 6 3 ...
Page 152: ...Troubleshooting Section 6 Troubleshooting 6 4 ...
Page 185: ......