- 37 -
Individual max light level display mode
The maximum receiving light level of the selected beam is
displayed.
The beam number is displayed on the top row. The maximum
receiving light level corresponding to the beam number is
displayed on the bottom row.
Threshold teach
TCH
(1)
(2)-1
P.123
Max-Min Level
Go to
2. threshold
calculate.
(2)-2
Individual Level
U/
D
Individual Level
A.123
A.122
L/R
Individual Max. Level
L/R
(2)-3
L.123
Individual Max. Level
U/
D
L.122
L/R
U/
D
ENTER Key
CANCEL Key
[L]/[R] Key
[UP]/[DOWN] Key
Beam number is
changed
Beam number is
changed
Go to (1)
Go to
2. threshold calculate.
Go to (1)
Go to
2. threshold calculate.
The fourth figure of the bottom row indicator of “(2)-1” indicates that
the approximate beam position having the minimum light level.
The beam positions of the sensor are divided in to three groups, top,
middle, and bottom, and displayed as show in the figure below. (The
bottom position means the side with power supply lines.)
Max-Min Level
Lower position:
Top
Lower position:
Middle
Lower position:
Bottom
- 38 -
2. Calculate the optimal value of ON threshold level and adjust
manually.
The sensor automatically calculates the optimal value of
ON-threshold on the basis of the minimum light level. After automatic
calculation is completed, “Good” is displayed on top row and the
calculated ON-threshold is displayed on bottom row.
Additionally, the displayed ON-threshold value can be adjusted
manually. ON-threshold can adjust in the range of 18 to 100.
NOW CALC
ON-threshold calculate
(1)
Good 20
(2)
Adjustment of ON-threshold
Calculate
complete
U/
D
Good 19
(2)-1
Adjustment of ON-threshold
Manual adjustment of
ON-threshold
Go to 1. Display for receiving
light level value No.(2)-1
Go to 3. ON-threshold
write in to sensor
ENTER
CANCEL
One-point advice:
Adjust beams of the sensor with this function so that the
minimum receiving light level becomes higher. By doing this, the
sensor detects stably.