- 23 -
①
②-1
②-2
②-3
②-4
②-5
Go to
②-3
Go to
②-4
Go to
②-5
Floating blanking
Sequential mode
Function Valid
Floating beam no.
Outermost beam invalid
Function valid
Floating beam no.
Sequential mode
Outermost beam invalid
Send to sensor
Setting completed
Error
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
1:1 floating beam
Go to
①
after 1 sec.
2:2 floating beams
3:3 floating beams
CLR: floating beams
clear
2.FLO
1.FUN
②-1-1
2. NO.
3.SEQ
4.O.B.I.
SEND
②-2-1
②-3-1
②-4-1
②-5-1
Go to
②-2
ON:Valid
OFF:Invalid
ON:Valid
OFF:Invalid
ON:Valid
OFF:Invalid
GOOD
ERR
- 24 -
8.3 Auxiliary
output
<F3SN, F3SH>
This is a non-safety related output used to display a status.
This output cannot be used for the purpose of safety.
This can be selected to the following output;
1. Dark ON
2. Light ON
3. Light diagnosis
4. Lockout
5. Outermost beam monitoring
6. Blanking monitoring
7. Specified beam
For detail of each output, please refer to ANNEX1 INDEX.
<Note>
Because F3SH does not have fixed blanking function, “6. Blanking
monitoring” is not selectable.
8.4 Output2
<F3ZN>
This is a output of F3ZN used to display a status.
Available signals are the same as 8.3 Auxiliary output.