- 59 -
F3ZN
Function
Sensor
CH
Mode display
(Top row)
Mode display
(Bottom row)
ALL Function
Valid
/
Invalid
Teach
Teaching / Clear
1 to 3
Manual
Valid / Invalid (Set each beam)
ALL
Fixed blanking
-
Send to sensor
ALL Function
Valid
/
Invalid
Floating Beam
1 / 2 / 3 / Clear
Sequential beam
Valid / Invalid
1 to 3
Outermost beam invalid Valid
/
Invalid
ALL
Floating blanking
-
Send to sensor
Setting value
L-on / D-on / Light diagnosis
/ Lockout / Outermost beam /
Specified beam / Blanking
Output2
-
Send to sensor
Setting value
L-on / D-on / Light diagnosis
/ Lockout
External indicator
output
-
Send to sensor
Min. light level
Threshold value
Threshold adjustment
-
Send to sensor
Initialization
Cancel / Send to sensor
Setting value
0000 to 9999
ALL
ID setting
-
Send to sensor
SET/
MONITOR
1 to 3 Error log view
Error log view
Error code
1 to 3 Upload
Bank number
1 to 3 Download
Bank number
COPY
–
Bank lock
Bank number
LOCK / FREE
Lock object
All / Only F3SN+F3SH / Only
F3ZN / Clear
– Setting
lock
Input password
Input 4 digit number
Old password
Input 4 digit number
– Change
password
New password
Input 4 digit number
No. of fixed zones
Clear, 0 to 3
Max. no. of Fixed
beams
Clear, 1 to 9
PROTECT
– Setting
limitation
Max. no. of floating
beams
Clear, 0 to 3
- 60 -
ANNEX3 ERROR CODE LIST
Error code
Contents and remedy
A8, AA
Wiring error
Wiring is not performed correctly.
Please confirm a sensor instruction manual and check wiring.
A3
Error of the EDM function
Feed back signal is not returned to EDM line or a relay may be
welding.
Please improve wring or change a relay so that feed back signal is
returned correctly.
A7, 32
Communication error
The communication error has occurred by the wiring error, or a noise.
Please improve installation environment and wiring environment.
When you cannot solve, please contact our sales office.
35 to 38, 27
OSSD error
OSSD outputs are shorted together or OSSD output is shorted to
+24V line, 0V line, or the other I/O line or failure of OSSD output
circuit.
Please improve wiring. When you cannot solve, please contact our
sales office.
A2
Error by interference light
The sensor receives interference light from another sensor. Please
adjust an optical-axis including that of surrounding sensors. In
addition, please do interference light countermeasure as described in
sensor instruction manual.
A0, A1, A4, A5
Incorrect configuration on sensor connection
The model of emitter and receiver differs. When sensor is connected
in series, sensor connection is incorrect. Please check the sensor
model and connection status.
Other codes
Internal error
Irreparable Error has occurred inside the sensor. Please contact our