- 45 -
10 PROTECT
WARNING
F39-MC must be managed and used only by qualified persons.
Operation by un-qualified persons could create a hazardous
condition which may lead to a loss of safety function.
This mode enables the lock function which disallows setting changes
without a password, setting limitations can also be set to restrict the
changes that can be made.
<Note>
This function resides with the F39-MC and not the sensor. If the
F39-MC is not protected, it could enable un-authorized persons to
change the setting of the sensors.
We strongly recommend, to set “Protect” to all purchased F39-MCs.
Switching modes is illustrated below;
Section10.1(46page) Section10.2(47page) Section10.3(48page)
[UP][DOWN]Key
Blinking
1.Setting lock
3.Setting limitation
2.Change password
1.S.LC
2.PAS
3.LMT
- 46 -
10.1 Setting
lock
Prohibit setting change. Select from [Lock all sensors], [Lock only
F3SN+F3SH], [Lock only F3ZN] or [Unlock all sensors].
A password (4 digit number) is required to change locked status.
When locked, the following is prohibited;
-Sending to sensor in Set/Monitor function
-Download to sensor in Copy function
Enter password except current
setting is "Unlock".
Setting lock
Setting lock
Enter password
Setting completed
RST:Unlock all
sensors
ALL:Lock all
sensors
SN.SH:Lock F3SN &
F3SH
ZN:Lock only
F3ZN
Enter 4 digit number (0000 to 9999)
ERR:Password
unmatched
OR
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
①
1.S.LC
②
③
④
0000
GOOD
Go to ①
after 1 sec