- 31 -
8.7 Start
interlock
<F3SN, F3SH>
When this function is ON, the outputs remain in the OFF-state (i.e.
interlock state) after power ON. Interlock state can be released by a
manual reset when there are no obstructions in the detection zone.
CAUTION
This function is valid only when using manual reset mode. When in
auto reset mode, the start interlock function is automatically
disabled.
②-1
②-2
Start interlock
Setting completed
Error
Function Valid
Function Valid
Send to sensor
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
Go to
①
after 1 sec.
①
6.SIL
1.FUN
SEND
②-1-1
②-2-1
GOOD
ERR
Go to
②-2
ON:Valid
OFF:Invalid
- 32 -
8.8 Restart
interlock
<F3SN, F3SH>
When this function is ON, the outputs remain in their OFF-state (i.e.
interlock state) when sensor is interrupted. Interlock state can be
released by a manual reset when there are no obstructions in the
detection zone.
CAUTION
This function is valid only when using manual reset mode. When in
auto reset mode, the start interlock function is automatically
disabled.
②-1
②-2
Setting completed
Error
Function Valid
Function Valid
Send to sensor
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
Go to
①
after 1 sec.
①
1.FUN
SEND
②-1-1
②-2-1
GOOD
ERR
Go to
②-2
ON:Valid
OFF:Invalid
Restart interlock
7.RIL