- 19 -
<F3SN, F3ZN>
About F3SN, it becomes the following displays by the serial number.
Go to
②-2
001:Select beam num.
①
z
②-1
②-2
②-3
②-4
Go to
①
after 1 sec.
Go to
②-4
after 1 sec
Fixed blanking
Error
Function Valid
Beam select
(manual)
Beam select
(manual)
Beam select
(manual)
Setting completed
Function Valid
Beam select (Teach)
Beam select (Teach)
Send to sensor
ON:Valid
OFF:Invalid
ON:Beam selected
OFF:Beam un-selected
ENT:Beam(s) selected
Go to
②-3
after 1 sec
CLR:Clear selected
beam(s)
When "teached", blocked
beams are selected.
Note: When "Enter" key
pressed with no blocked
beams, "Err" is displayed.
OR
OR
Blinking
[Cancel] Key
[Enter] Key
[Up][Down] Key
1.FIX
②-1-1
1.FUN
2.TCH
②-2-1
3.MAN
②-3-1
②-4-1
SEND
②-2-2
GOOD
ERR
②-3-2
GOOD
ERR
②-3-3
GOOD
ERR
- 20 -
Example of how to set fixed blanking.
Example1:Set Fixed Blanking using "teaching"
②-1-1:Select "1.Fun-on"(Function valid)
Place an object where you want to be "blanked"
②-2-1:Select "2.tch-Ent"(Beams select)
②-4:Send setting to sensor
Setting completed
[good] displayed
ONE POINT:
After setting has completed, you can confirm the
blanked beam numbers by using ②-3:Manual Beam
select menu.
[good] displayed
[Err] displayed・・・Object is not mounted properly.
Replace it and try ②-2 again.
[Err] displayed・・・Couldn't send setting to sensor.
Check wiring, etc. and try again from the beginning
Example2:Set Fixed Blanking using "manual"
②-1-1:Select "1.Fun-on"(Function valid)
②-3:Select "3.man"(manual beam select)
②-3-1:Input beam number to be "blanked"
②-3-2:Select "on"(beam selected)
②-4:Send setting to sensor
Setting completed
[good] displayed
[good] displayed
In order to "blank" more than one beam, repeat
Select beam number -> select "on" -> [CANCEL] Key
command, and push [ENTER] key at the end.
[Err] displayed・・・Couldn't send setting to sensor.
Check wiring, etc. and try again from the beginning
[Err] displayed・・・Wrong beam number was inputted.