- 55 -
Terms Explanation
Start interlock function
[F3SN,
F3SH]
Outputs remain in the OFF-state (i.e. Interlock state) after power
ON. Interlock state can be released by a manual reset when
there are no obstructions in the detection zone.
This function is valid only when using manual reset mode.
Surveillance mode
(Fixed blanking)
It is the function which supervises whether a blanked beam
becomes clear. “setting release at the light receiving condition”
or “lockout mode at the light receiving condition” can be chosen.
Threshold teach
It is the function which unites ON-threshold of a sensor with the
receiving light level value of a sensor, and is changed into the
optimal value.
Test input-ON
(Ext. indicator)
When a test input is ON, external indicator lights up. If a test
input turns ON, a sensor will operate an external diagnostic
function.
T
Test input-OFF
(Ext. indicator)
When a test input is OFF, external indicator lights up. If a test
input turns on, a sensor will operate an external diagnostic
function.
- 56 -
ANNEX2 FUNCTION LIST (according to sensor type)
F3SN
Function
Sensor
CH
Mode display
(Top row)
Mode display
(Bottom row)
ALL
Function Valid
/
Invalid
Teach
Teaching / Clear
Manual
Valid / Invalid (Set each beam)
1 to 3
Surveillance mode
(Note1)
Lockout mode at the light
receiving condition / Setting
release at the light receiving
condition
ALL
Fixed blanking
-
Send to sensor
ALL
Function Valid
/
Invalid
Floating Beam
1 / 2 / 3 / Clear
Sequential beam
Valid / Invalid
1 to 3
Outermost beam invalid Valid
/
Invalid
ALL
Floating blanking
-
Send to sensor
Setting value
L-on / D-on / Light diagnosis /
Lockout / Outermost beam /
Specified beam / Blanking
Auxiliary output
-
Send to sensor
Setting value
L-on / D-on / Light diagnosis /
Lockout / Test input-ON
(Note1) / Test input-OFF
(Note1) / Blanking setting
(Note1)
Lighting pattern setup
(Note1)
Light / Blink in a cycle of 0.5
seconds / Blink in a cycle of
1 seconds / Blink in a cycle
of 2 seconds
External indicator
output
-
Send to sensor
Function Valid
/
Invalid
Setting time
100 to 600ms; every 5ms
External device
monitoring
-
Send to sensor
Function Valid/Invalid
Start interlock
-
Send to sensor
Function Valid
/
Invalid
Restart interlock
-
Send to sensor
Initialization
Cancel / Send to sensor
Setting value
0000 to 9999
ALL
ID setting
-
Send to sensor
Receiving light level
value view
Receiving light level value
Adjusting threshold
ON-threshold
1 to 3 Threshold teach
(Note 2)
-
Send to sensor
SET/
MONITOR
1 to 3 Error log view
Error log view
Error code
1 to 3
Upload Bank
number
1 to 3
Download Bank
number
COPY
–
Bank lock
Bank number
LOCK / FREE