- 1 -
1 DESCRIPTION
The Setting consol Model F39-MC11 (hereafter referred to as F39-MC)
can be connected to Safety Light Curtain Series—Model F3SN,
Multi-beam Safety Sensor series—Model F3SH, and Area Scanner
series—Model F3ZN. The F39-MC allows you to change or monitor the
setting of these sensors.
Available setting functions are as follows;
Function Setting F3SN
F3SH
F3ZN
Fixed blanking
Floating blanking
Auxiliary output
Output2
External indicator output
External device monitoring
Start interlock
Restart interlock
Threshold adjustment
Setting initialization
ID setting
Threshold teach *
Monitor/
Set
Error log view
Copy Upload
Download
Bank lock
Protect Setting
lock
Change password
Setting limitation
: Accessible
* For the sensor having the specific serial number, this function is
unavailable.
Refer to “ 1.2 Available function and Sensor serial number ”.
- 2 -
1.1
Outline of operation procedure
Shown in the following flow chart.
⑨Power on sensor(s) and
confirm correct function
by the test.
Outline of operation
procedure
Setting completed.
(Able to normal use)
See section 6
See section 7
See section 4.1
See section 4.3
See section 5
①Mount branching connector
②Connect cable and F39-MC
③Power on both sensor(s)
and F39-MC
④Select function
(MONITOR/SET, COPY,
PROTECT)
⑤Select channel of sensor
to be set
⑥Select sensor function to
be set, and change value
⑦Send changed setting to
sensor(s)
⑧Power OFF, and detach
F39-MC and cable
See section 8 to 10
See section 11
See section 8 to 10