Page 1: ...2ZQHU V 0DQXDO VSR 3 YLQWDJH VSULQJ UHYHUE ...

Page 2: ...d parties 3 Heed all warnings 4 Follow all instructions 5 Do not use this apparatus near water 6 Only clean the product when it is not connected to the mains power supply Clean only with a dry cloth 7 Do not block any ventilation openings Install in accordance with the manufacturer s instructions 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus incl...

Page 3: ...ose this equipment to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on the equipment 18 The mains plug of the power supply cord shall remain readily accessible Installation Ensure that the room in which you use this product is wired in accordance with the local electrical code and checked by a qualified inspector Only use this product indoors Do not ...

Page 4: ...VSR 3 all level controls GAIN and OUTPUT LEVEL as well as the level controls of the following equipment must be set to zero On the VSR 3 that means the far left knob position Switch off the VSR 3 before connecting 1 Connect the provided power cord to the MAINS IN 10 jack 2 Connect on of the input jacks 1 or 7 of the VSR 3 to the audio output of your signal source i e an instrument guitar synthesiz...

Page 5: ...encies will be boosted when turning it to the left on the opposite high frequencies will be boosted when turning it to the right Center position is 12 o clock 4 MIX This controller sets the value between direct and reverberated signal If the knob is set completely to the left only the direct signal can be heard The fare right position means no direct signal but 100 reverberation 5 OUTPUT LEVEL Thi...

Page 6: ...e effect stop function can be connected to this jack The switch on the front panel 6 is out of use when a plug is used with this jack 10 MAINS IN The power cord needs to be plugged in here in order to get the VSR 3 operational The VSR 3 has a switching power supply and can be used with AC voltages from 90V to 240V 50 60Hz 11 POWER This switch turns the VSR 3 on off The LED above the EFFECT STOP sw...

Page 7: ...dance 10kΩ Outputs Level 1 0dBu Level 2 20dBu Signal To Noise ratio Effect 70dBu Direct 80dBu THD Noise Direct 0 1 Product Properties Power Consumption 5VA Power 90 240V 50 60Hz Controllers Gain Tone Mix Output Level Switches Effect Stop footswitch connector Power Chassis 19 1U ca 190mm deep Weight 2 6kg Owner s Manual VERMONA VSR 3 vintage spring reverb 7 ...

Page 8: ... conditions and installation arrangements acc to operating manual EN61000 3 2 EN 61000 3 3 EN 55013 EN 55020 EN 60065 according to the provisions of the regulations 2004 108 EG and 2006 95 EG HDB electronic GmbH Badesteig 20 08265 Erlbach GERMANY Phone 49 37422 25 30 Fax 49 37422 23 97 Email info vermona com Web http www vermona com Owner s Manual VERMONA VSR 3 vintage spring reverb 8 ...