background image

 

PNSPO!

 
 

Model 

F39-MC11

(ver. 3)

 

 

Setting Console 

 

 

 INSTRUCTION  MANUAL

           

 

 
 
 
Thank you for selecting OMRON product. This manual primarily 
describes precautions required in installing and operating the product. 
Before operating the product, read this manual thoroughly to acquire 
sufficient knowledge of the product. For your convenience, always keep 
this manual at hand. 
 
 
 
 
 
 
 
 
 
 

                             

 

©OMRON Corporation 2001-2003 All Rights Reserved. 

 
 
 

                                                                     

 

 

 

i

Read and Understand this Instruction Manual 

Please read and understand this instruction manual before storing, 
installing, programming, operating, maintaining, or disposing of the 
products.  Please consult your OMRON representative if you have any 
questions or comments.     
 
 

Warranty, Limitations of Liability 

WARRANTY

 

OMRON's exclusive warranty is that the products are free from 
defects in materials and workmanship for a period of one year (or 
other period if specified) from date of sale by OMRON. 
 
OMRON MAKES NO WARRANTY OR REPRESENTATION, 
EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, 
MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE 
OF THE PRODUCTS.    ANY BUYER OR USER ACKNOWLEDGES 
THAT THE BUYER OR USER ALONE HAS DETERMINED THAT 
THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF 
THEIR INTENDED USE.  OMRON DISCLAIMS ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED.     

LIMITATIONS OF LIABILITY

 

OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, 
INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS 
OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE 
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, 
WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.     
 
In no event shall the responsibility of OMRON for any act exceed the 
individual price of the product on which liability is asserted.     
 
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR 
WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE 
PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE 
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, 
AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, 
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR 
REPAIR.   

 
 

Summary of Contents for F39-MC11

Page 1: ...m date of sale by OMRON OMRON MAKES NO WARRANTY OR REPRESENTATION EXPRESS OR IMPLIED REGARDING NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ANY BUYER OR USER ACKN...

Page 2: ...EN DESIGNED TO ADDRESS THE RISKS AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM PROGRAMMABLE PRODUCTS OMRON shall not be respo...

Page 3: ...volves a change of the safety distance Always recalculate and re measure the safety distance to confirm that it meets the applicable standards after the change Failure to do so may cause the machine t...

Page 4: ...nal indicator output 27 8 6 External device monitoring 30 8 7 Start interlock 31 8 8 Restart interlock 32 8 9 Threshold adjustment 33 8 10 Setting initialization 34 8 11 ID setting 35 8 12 Threshold t...

Page 5: ...load Bank lock Protect Setting lock Change password Setting limitation Accessible For the sensor having the specific serial number this function is unavailable Refer to 1 2 Available function and Sens...

Page 6: ...02 or aaaabcc aaaa can be any numeric characters b can be any alphanumeric characters cc is greater than 03 The functional group B The following serial numbers correspond to the functional group B Ser...

Page 7: ...ector when F39 MC is not in use Brief description of Operation keys 6 CANCEL ENTER DOWN R L UP MONITOR SET COPY PROTECT FUNCTION 3 1 Communication connection indicator CONNECT This indicator will ligh...

Page 8: ...connector Emitter Receiver Emitter Receiver 8 4 2 Diagram for Wiring of Branching Connector Front View Pin No Signal 1 24 V 24VDC 2 RS 485 A 3 0V 4 RS 485 B CAUTION The F39 MC receives its power from...

Page 9: ...with the power supply of the sensor When the F39 MC power is ON it confirms its connection to sensor When connection is succeeded it displays as follows Communication connecting indicator is lit Displ...

Page 10: ...e item of respective function Monitor Set Section8 page14 Copy Section9 page41 Protect Section10 page45 DOWN UP MONITOR SET COPY PROTECT FUNCTION MONITOR SET COPY PROTECT FUNCTION MONITOR SET COPY PRO...

Page 11: ...the setting can only be done under observance of laws standards which are related to safe operation of the product This function enables the monitoring of current set values and functions of the senso...

Page 12: ...a power supply should be dropped a sensor may not carry out normal operation 16 8 1 Fixed blanking F3SN F3ZN CAUTION In order prevent access to a dangerous area fixed barrier guards must be placed in...

Page 13: ...clear Note Models produced before April 2002 can not use setting of Surveillance mode Sensors which has specific serial number also can not use the setting If the surveillance mode is set to above mo...

Page 14: ...n valid Place an object where you want to be blanked Select 2 tch Ent Beams select Send setting to sensor Setting completed good displayed ONE POINT After setting has completed you can confirm the bla...

Page 15: ...OFF when 2 or more beams are blocked 22 CAUTION Use of floating blanking function involves a change of the safety distance Always recalculate and re measure the safety distance to confirm that it meet...

Page 16: ...alid OFF Invalid ON Valid OFF Invalid GOOD ERR 24 8 3 Auxiliary output F3SN F3SH This is a non safety related output used to display a status This output cannot be used for the purpose of safety This...

Page 17: ...cked beams Err is displayed 3 AUX 1 D ON 2 L ON 3 L DG 4 L OU 5 O B M 6 BLN 7 SPC GOOD ERR SEND GOOD ERR 26 Setting completed Error Send to sensor Specified beam Blanking monitor Outermost beam monito...

Page 18: ...inks in a cycle of 1 seconds bln 3 It blinks in a cycle of 2 seconds Note 1 F3ZN can set up only 1 4 2 There are some which cannot set up above 5 7 by the serial number about F3SN and F3SH 3 There are...

Page 19: ...lfunction of external device which controls hazardous area of machine e g contact welding The determination time can be set in respect to the response time of relay being used The setting time must be...

Page 20: ...nter Key Up Down Key Go to after 1 sec 6 SIL 1 FUN SEND GOOD ERR Go to ON Valid OFF Invalid 32 8 8 Restart interlock F3SN F3SH When this function is ON the outputs remain in their OFF state i e interl...

Page 21: ...nsor Blinking Cancel Key Enter Key Up Down Key Go to after 1 sec 8 TH 18 SEND GOOD ERR 34 8 10 Setting initialization F3SN F3SH F3ZN This function returns the sensor setting to their default value Def...

Page 22: ...level value 2 Calculate the optimal value of ON threshold level and adjust manually 3 Write ON threshold level into sensor CAUTION Perform this function at the condition that all the beams of a senso...

Page 23: ...played as show in the figure below The bottom position means the side with power supply lines Max Min Level Lower position Top Lower position Middle Lower position Bottom 38 2 Calculate the optimal va...

Page 24: ...to 1 display for receiving light level value No 1 40 8 13 Error log view F3SN F3SH F3ZN The error log recorded in sensor is displayed The error log is written with error codes See the contents of err...

Page 25: ...ible For example copying from F3SN to F3ZN is not possible 2 Copying to sensor with different detection capability or beam gap is not possible Switch modes are illustrated below Section9 1 42page Sect...

Page 26: ...displayed as Good When a power supply should be dropped a sensor may not carry out normal operation Download Download Setting completed Error Select bank number using UP DOWN keys Note F3SN F3SH has o...

Page 27: ...illustrated below Section10 1 46page Section10 2 47page Section10 3 48page UP DOWN Key Blinking 1 Setting lock 3 Setting limitation 2 Change password 1 S LC 2 PAS 3 LMT 46 10 1 Setting lock Prohibit s...

Page 28: ...n qualified person Note Please remember changed password If you forget please contact OMRON 48 10 3 Setting limitation Limit the re settable functions in order to prevent hazardous setting by mistake...

Page 29: ...Go to after 1 sec RST Reset limitation RST Reset limitation Blinking Cancel Key Enter Key Up Down Key 50 11 DISCONNECT F39 MC After the setting has completed be sure to disconnect cable and F39 MC be...

Page 30: ...1 Mount correctly see section 4 2 Use power supply with enough capacity 2 Communication connection indicator of F39 MC will not lit or not conn is displayed Cause 1 F39 MC has powered on after sensor...

Page 31: ...rface displacement of beams or deterioration of LED Unstable condition indicates that the light level remains within 20 of threshold value 54 Terms Explanation Light ON Auxiliary output output2 Ext in...

Page 32: ...Manual Valid Invalid Set each beam 1 to 3 Surveillance mode Note1 Lockout mode at the light receiving condition Setting release at the light receiving condition ALL Fixed blanking Send to sensor ALL F...

Page 33: ...ator output Send to sensor Function Valid Invalid Setting time 100 to 600ms every 5ms External device monitoring Send to sensor Function Valid Invalid Start interlock Send to sensor Function Valid Inv...

Page 34: ...60 ANNEX3 ERROR CODE LIST Error code Contents and remedy A8 AA Wiring error Wiring is not performed correctly Please confirm a sensor instruction manual and check wiring A3 Error of the EDM function...

Page 35: ...X 13 2130AA Hoofddorp The Netherlands Phone 31 23 56 81 300 Fax 31 23 56 81 388 AUSTRIA OMRON Electronics G m b H Brunner Strasse 81 Box 323 A 1230 vienna Phone 43 1 801 90 0 Fax 43 1 804 48 46 BELGIU...