11
Connecting Temperature Controllers
Section 1-3
1-2-3
General Specifications
Note Current supplied to the Temperature Controllers is not included.
1-3
Connecting Temperature Controllers
1-3-1
Temperature Controller ID and Number of Connectable Units
The Temperature Controllers are connected alongside the DeviceNet Com-
munications Unit and the block is linked through the Terminal Units connected
to the back of the Temperature Controllers, as shown in the following diagram.
The DeviceNet Communications Unit differentiates each of the connected
Temperature Controllers according to unit numbers (0 to F). The Temperature
Item
Specifications
Supply voltage
DeviceNet power
supply
24 VDC (internal circuit)
External input power
supply
24 VDC (for RS-485 communications circuit/ Temperature Controllers)
Allowable voltage
range
DeviceNet power
supply
11 to 25 VDC
External input power
supply
20.4 to 26.4 VDC
Current consumption DeviceNet power
supply
45 mA max. (24 VDC: Current consumption of DeviceNet Communications
Unit)
External input power
supply
20 mA max. (24 VDC) (See note.)
Vibration resistance
10 to 55 Hz, 10m/s
2
for 2 hours each in X, Y, and Z directions
Shock resistance
150m/s
2
max. 3 times each in 3 axes, 6 directions
Dielectric strength
500 VAC 50 or 60 Hz 1min between DIN Track and entire terminal block
(DeviceNet connector) or between DIN Track and all terminals (terminal
sockets)
Insulation resistance
20 M
Ω
min. (at 100 VDC)
Ambient temperature
−
10 to 55°C (with no condensation or icing)
Ambient humidity
25% to 85%
Storage temperature
−
25 to 65°C (with no condensation or icing)
Enclosure rating
IP00
Dimensions
30
×
130
×
89.6 mm (W
×
D
×
H)
(When connected to an E5ZN-SCT24S Terminal Unit.)
Memory protection
EEPROM, 100,000 write operations (backup data)
Weight
100 g max. (not including Terminal Unit)
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
UNIT
BPS
POWER
ERROR
SD/RD
OUT1
OUT2
SUB1
SUB2
E5ZN
Up
Up
E5ZN Temperature Controllers
DeviceNet
Communications Unit
Summary of Contents for E5ZN-DRT
Page 3: ...iv ...
Page 5: ...vi ...
Page 9: ...x ...
Page 15: ...xvi EC Directives 6 ...
Page 83: ...68 Ladder Programming Examples Section 4 5 ...
Page 123: ...108 Sending Explicit Messages Section 6 5 ...
Page 135: ...120 Message Communications Characteristics Section 7 2 ...
Page 157: ...142 Index Unit status 57 85 user set allocations 43 61 V variable types C0 51 C1 51 C3 52 ...
Page 159: ...144 Revision History ...
Page 161: ...E5ZN DeviceNet Communications Unit Cat No H119 E1 01 OPERATION MANUAL ...