Section 1-5
%%
Configuration 1
All Counters as Simple Counters:
1, 2, 3…
1. No (DM-) configuration settings can be made. The Unit is ready to count and
will use all default DM-values. All data related to the Simple Counter is now
being exchanged between the PLC and the Unit in CIO-memory and available
for usage in the PLC Ladder Program.
2. Create and RUN a Ladder Program in the PLC. Refer to section 4
for details on the interface between the High-speed Counter
Unit and the CPU. Section 6-1
“Flow Control
” describes an application example
using the Simple Counter.
Refer to 3-2-1
for more details about the Simple Counter.
Configuration 2
All Counters as Circular or Linear Counter:
1, 2, 3…
1. Every Counter can now be separately (DM-) configured. For this purpose you
can use a Programming Console or CX-Programmer Support Software. The
configuration of the Counter Type (Linear or Circular Counter) is done by DM-
setting. Refer to section 3
for detailed informa-
tion about configuring the Unit.
2. Power up the PLC again or turn the Special I/O Unit Restart Bit to ON and then
OFF again (to transfer the DM-settings). All data related to Circular /Linear
Counters is now being exchanged between the PLC and the Unit in CIO-mem-
ory and available for usage in the Ladder Program.
3. Create and RUN a Ladder Program in the PLC. Refer to section 4
for details on the interface between the CS1W-High-speed
Counter Unit and the CPU. Refer to sections 6-2 to 6-5 for application examples
using Circular and Linear Counters.
Refer to 3-2-2
for more details
about both Counter Types. Refer to 4-1-2
"Special I/O Units Restart bits"
for more
information about restarting the Unit.
Configuration 3
Mixed Configuration Simple/Circular/Linear Counters:
1, 2, 3…
1. Every Counter that has been set to Circular/Linear Counter can now be (DM-)
configured. For this purpose you can use a Programming Console or CX-Pro-
grammer Support Software. The configuration of the Counter Type (Linear or
Circular Counter) is done by DM-setting. Refer to section 3
for detailed information about configuring the Unit. For the
Counters that have been configured for Simple Counter no (DM-) configuration
has to be done since the default (=0000) DM-settings are used for these
Counters.
2. Power up the PLC again or turn the Special I/O Unit Restart Bit to ON and then
OFF again (to transfer the DM-settings). All data related to Circular/Linear
Counters is now being exchanged between the PLC and the Unit in CIO-mem-
ory and available for usage in the PLC Ladder Program.
3. Create and RUN a Ladder Program in the PLC. Refer to section 4
for details on the interface between the High-speed Counter
Unit and the CPU. Refer to sections 6-2 to 6-5 for application examples using
Circular and Linear Counters.
Refer to 3-2-1
for more details about the Counter Types. Refer to 4-1-2
for more information about restarting the Unit.
W902-E2-03.book Seite 22 Donnerstag, 7. Oktober 2004 2:06 14
Summary of Contents for CS1W-CT021
Page 1: ...OPERATION MANUAL High speed Counter Units CS1W CT021 CS1W CT041 Cat No W902 E2 03...
Page 3: ...W902 E2 03 book Seite iv Donnerstag 7 Oktober 2004 2 06 14...
Page 5: ...W902 E2 03 book Seite vi Donnerstag 7 Oktober 2004 2 06 14...
Page 39: ...W902 E2 03 book Seite 24 Donnerstag 7 Oktober 2004 2 06 14...
Page 59: ...A 2 Section 2 3 W902 E2 03 book Seite 44 Donnerstag 7 Oktober 2004 2 06 14...
Page 155: ...4 Section 4 6 W902 E2 03 book Seite 140 Donnerstag 7 Oktober 2004 2 06 14...
Page 199: ...G W902 E2 03 book Seite 184 Donnerstag 7 Oktober 2004 2 06 14...