F"")"-$).#+
Section 5-2
$''
Error History Log File
Up to a maximum of 30 errors can be logged in chronological order inside the
High-speed Counter Unit, constituting the Error History Log File. If multiple errors
are active at the same time every error (-code) can be read sequentially into CIO
(n+17, n+18) by using the Read Next Error bit. Every next error is read from the
Error History Log File at the rising edge of the Read Next Error bit. If you attempt
to read an error after the last error in the list has been read, the value of zero will
be returned. Now you can scroll through the same error list again from the next ris-
ing edge of the Read Next Error bit.
5-2-1
DM-configuration errors
DM-configuration errors are detected during initialisation after the Unit has been
powered up or restarted. DM-configuration errors can also be detected after the
IOWR-instruction “(Re) Configure Unit” has been issued (refer to 4-5-3-4
“(Re)
Configure Unit”
). In case a DM-configuration error is detected the Unit will report
the error and stop operating. The error(s) can be read in CIO using the “Read Next
Error” bit.
General Setting:
n+1
Read Next Error
0
→
1 = Read Next Error
15 14 13 12 11 10 9
8
7
6
5
4
3
2
1
0
Error Code 1
Error Code 2
Error
Description
0300
Offset (BCD)
Out of Range
The DM-setting located at
(Nx100) +
Offset
is Out of Range (N = Machine Number).
0310
Offset (BCD)
Invalid BCD-code
The DM-setting located at
(Nx100) +
Offset
is an invalid BCD-code (N = Machine
Number).
(The range of a valid BCD-code for a digit is
0-9. If one or more digits is within range A-F an
invalid BCD-code is specified).
0311
Offset (BCD)
Invalid Initial
Counter Value
The Initial Counter Value located at
(Nx100) + Offset
is outside the counting range that
is set for that Counter (N = Machine Number).
0320
Offset (BCD)
Invalid Rate
Range Limits
Upper Rate Range Limit
≤
Lower Rate Range
Limit of the Rate Range located at
(Nx100) + Offset
(N = Machine Number).
0320
Counter
No.
Range
No.
(BCD)
Invalid
Range Limits
Upper Range Limit < Lower Range Limit.
Counter
No.
indicates the Linear Counter number and
Range No.
indicates the Range number.
W902-E2-03.book Seite 144 Donnerstag, 7. Oktober 2004 2:06 14
Summary of Contents for CS1W-CT021
Page 1: ...OPERATION MANUAL High speed Counter Units CS1W CT021 CS1W CT041 Cat No W902 E2 03...
Page 3: ...W902 E2 03 book Seite iv Donnerstag 7 Oktober 2004 2 06 14...
Page 5: ...W902 E2 03 book Seite vi Donnerstag 7 Oktober 2004 2 06 14...
Page 39: ...W902 E2 03 book Seite 24 Donnerstag 7 Oktober 2004 2 06 14...
Page 59: ...A 2 Section 2 3 W902 E2 03 book Seite 44 Donnerstag 7 Oktober 2004 2 06 14...
Page 155: ...4 Section 4 6 W902 E2 03 book Seite 140 Donnerstag 7 Oktober 2004 2 06 14...
Page 199: ...G W902 E2 03 book Seite 184 Donnerstag 7 Oktober 2004 2 06 14...