![background image](http://html1.mh-extra.com/html/omron/3g3ax-mx2-crt-e/3g3ax-mx2-crt-e_user-manual_740779163.webp)
A - 13
Appendices
CompoNet Communications Unit User’s Manual (I582-E1)
A-2
A
C Drive Obje
ct Spec
ificat
ion
s
A
A-2-
2 Contr
ol
S
up
ervisor Object (Class 29
h
ex)
Instance
(hex)
Attribute
(hex)
Name
Description
Setting
Range
Default
Read Write
Size
01
0F
Control From
Net Run Signal
Input Status
0: Follow the setting of param-
eter A002
1: CompoNet
----
----
Yes
No
BOOL
10
CompoNet Fault
Mode
Indicates the inverter opera-
tion on network error.
0: Inverter Fault/Trip and stop
(P045 = 1)
1: Ignore (P045 = 2)
2: Vendor-specific
----
2
Yes
Yes
UINT
11
Force Fault/Trip
Communica-
tions External
trip Input
Inverter's External trip (EXT)
input
----
0
Yes
Yes
BOOL
12
Force Status
Communica-
tions External
trip Input Status
External trip (EXT) input sta-
tus
0: Communicating
1: Fault detected
----
0
Yes
No
BOOL
14
Net Idle Mode
Indicates the inverter opera-
tion on network idle mode.
0: Stop (P048 = 4)
1: Ignore (P048 = 2)
2: Vendor-specific
----
2
Yes
Yes
USINT
64
Drive State
Detail
Inverter Drive State Detail
value:
0 :Stopping
1 :Running
2 :Jogging
3 :Free running
4 :Direct current DC braking
5 :Restart (Retry)
Error detected (Deceler-
ated stop)
7 :Restart (Retry)
in process
8 :Waiting for restart
(retry)
10 :Fault/Trip
11 :Undervoltage condition
----
----
Yes
No
USINT
65
Trip Cause
Returns a direct Trip cause
(E01 to E99).
----
----
Yes
No
USINT
66
Free Run
Enables/disables free run.
0: Ignore
1: Free run enabled
----
0
Yes
Yes
BOOL
Summary of Contents for 3G3AX-MX2-CRT-E
Page 94: ...3 Network Startup 3 36 CompoNet Communications Unit User s Manual I582 E1...
Page 118: ...4 Remote I O 4 24 CompoNet Communications Unit User s Manual I582 E1...
Page 134: ...5 Message Communications 5 16 CompoNet Communications Unit User s Manual I582 E1...
Page 167: ...I 1 I CompoNet Communications Unit User s Manual I582 E1 Index...
Page 171: ......