2 - 5
2 CompoNet Communications Unit Mounting and Wiring
CompoNet Communications Unit User’s Manual (I582-E1)
2-1 Na
me an
d Set
ting
of
Each Co
mp
oNe
t
C
o
m
m
un
icati
ons Unit
Com
p
o
n
en
t
2
2-
1-3 R
otary Switche
s
The rotary switches are used to set the node address of the CompoNet Communications Unit. Set the
node address as a decimal number between 0 and 63.
Set the 10s digit on the left rotary switch and set the 1s digit on the right rotary switch. The setting of the
switches is updated when the Unit power supply is cycled.
Additional Information
There are two ways of configuring the CompoNet node address.
• Set the node address by the rotary switches to a valid value in the range 0 to 63.
• Set the node address by inverter parameter P190. Set the rotary switches to an invalid
value (between 64 to 99) to use inverter parameter P190.
2-1-3
Rotary Switches