3 Network Startup
3 - 32
CompoNet Communications Unit User’s Manual (I582-E1)
3
In the Advanced Options: [Via PLC (CompoNet)] window, configure the following two set-
tings.
• CompoNet node addresses: Select each node address of the CompoNet Master Unit and the
inverter (CompoNet Communications Unit).
• [Gateway PLC]: Click the [Settings] button in the [Gateway PLC] section and select the
Device Type and the Network Type.
4
When the above settings are done, use the [OK] button to close all the windows and click
the [Autodetect] button.
The Autodetect function starts to automatically create a new drive project.