Appendices
A - 8
CompoNet Communications Unit User’s Manual (I582-E1)
Precautions for Correct Use
Precautions for Correct Use
Instances 1 to 3 correspond to the inverter's multi-function output terminals P1/P2 and the
relay output terminal.
Instances 1 to 6 correspond to the inverter's multi-function output terminals P1 to P5 and the
relay output terminal.
A-1-6
Discrete Output Point Object (Class 09 hex)
Supported Service Codes
Table A-11 Discrete Output Point Object - Supported Service Codes
Service Code No. (hex)
Service Description
0E
Reads Attribute data.
10
Writes Attribute data.
Object Details
Table A-12 Discrete Output Point Object - Object Details
Instance
(hex)
Attribute
(hex)
Name
Description
Setting
Range
Default
Read Write
Size
01 to 06
03
Value
Terminal state
0: OFF
1: ON
----
----
Yes
Yes
BOOL