![background image](http://html1.mh-extra.com/html/omron/3g3ax-mx2-crt-e/3g3ax-mx2-crt-e_user-manual_740779053.webp)
2 - 11
2 CompoNet Communications Unit Mounting and Wiring
CompoNet Communications Unit User’s Manual (I582-E1)
2-2 In
stal
latio
n
2
2-
2-2 Mo
untin
g Procedure o
f CompeNet
Communications Unit on RX-
ser
ies Inverter
2
Cut out the two plastic break-outs from the
front cover.
Make sure no sharp edges remain.
3
Reinstall the front cover and tighten the
screws.
4
Connect the connector of inverter connection
PCB of CompoNet Communications Unit to the
connector of inverter.
Method:
First align the small hole (B) on the inverter con-
nection PCB with the guide-post (D) in the inverter.
Then, align the larger hole on the inverter connec-
tion PCB (C) with the threaded hole (F) in the
inverter.
Push the inverter connector into place.
A
B
C
F
E
D