The ‘Record Interval’ stores sensor subtype of Thermocouple or RTD based on
the configuration of the device. The record Interval byte details are given in the
table below.
Table 11-2: Allotment Bits of Fields at Record Interval
Data Logging
11
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Description
X
X
X
X
X
0
0
1
10 samples/1 second
X
X
X
X
X
0
1
0
1 sample/1 second
X
X
X
X
X
0
1
1
1sample/10 seconds
X
X
X
X
X
1
0
0
1 sample/30 seconds
X
X
X
X
X
1
0
1
1 sample/60 seconds
X
X
X
X
1
X
X
X
Indication for start
of fresh logging
For TC Board Only
0
0
0
1
X
X
X
X
J Type thermocouple
0
0
1
0
X
X
X
X
K Type thermocouple
0
0
1
1
X
X
X
X
T Type thermocouple
0
1
0
0
X
X
X
X
E Type thermocouple
0
1
0
1
X
X
X
X
R Type thermocouple
0
1
1
0
X
X
X
X
S Type thermocouple
0
1
1
1
X
X
X
X
B Type thermocouple
1
0
0
0
X
X
X
X
C Type thermocouple
1
0
0
1
X
X
X
X
N Type thermocouple
For RTD Board Only
0
1
X
X
X
X
X
X
PT100 type RTD
1
0
X
X
X
X
X
X
PT1000 type RTD
X
X
0
1
X
X
X
X
American curve
X
X
1
0
X
X
X
X
European curve
11-2