Error Handling and Troubleshooting
91
22.
Reconnect the ground cable (Allen wrench), the thermal sensor, and two lamp power connectors.
[43] Cable, Sensor and Power Connectors
[43] Cable, Sensor and Power Connectors
23.
Close the gantry doors.
24.
Turn the printer power ON.
Note:
In order to track lamp usage and to estimate lamp replacement schedules, always re-set the usage statistics after
replacing a lamp bulb.
Re-set the Lamp Usage Statistics
1.
In the Operator/Maintenance menu press the MENU button until you see Lamp Usage.
2.
Press ACCEPT to enter the Lamp Usage menu. Press MENU until you see “reset lamp usage”.
3.
Press ACCEPT to see “reset lamp usage: lamp B”. If you have changed the Blot side lamp, press ACCEPT. If you changed
the Carriage side lamp, press the + or - key to select lamp C, then press ACCEPT.
4.
Press ACCEPT one more time and the lamp use time and number of strikes will be re-set to zero.
Summary of Contents for Arizona T220UV
Page 1: ...Arizona T220UV User Guide...
Page 5: ...5 Arizona T220UV User Guide Chapter 1 Introduction...
Page 10: ...10 T220UV User Guide...
Page 11: ...11 Arizona T220UV User Guide Chapter 2 Product Overview...
Page 15: ...15 Arizona T220UV User Guide Chapter 3 Safety Information...
Page 30: ...30 T220UV User Guide...
Page 31: ...31 Arizona T220UV User Guide Chapter 4 User Interface...
Page 40: ...40 T220UV User Guide...
Page 41: ...41 Arizona T220UV User Guide Chapter 5 How to Operate the Arizona T220UV...
Page 63: ...63 Arizona T220UV User Guide Chapter 6 Ink System Management...
Page 71: ...71 Arizona T220UV User Guide Chapter 7 Media Management...
Page 77: ...77 Arizona T220UV User Guide Chapter 8 Error Handling and Troubleshooting...
Page 92: ...92 T220UV User Guide...
Page 93: ...93 Arizona T220UV User Guide Chapter 9 Printer Maintenance...
Page 114: ...114 T220UV User Guide...