![background image](http://html2.mh-extra.com/html/obr/pcm2/pcm2_installation-and-user-manual_3166195091.webp)
Control Systems
OBR Control Systems Inc
OBR Control Systems Inc
Telephone : +1 (248) 672-3339
32233 West 8 Mile Road
www.obrcontrolsystems.com
Livonia, Michigan 48152
USA
91 / 92
*) Current draw based on typical race car wiring quality with maximised performance of Deutsch
Autosport connector specifications.
17.2.7
Sensor supplies & warning light
Number of 5 volts reference sensor supplies
4; each 1.0 A @ 5 volts
17.2.8
Tristate Supplies
Number of tri-state logic outputs
4
Voltage level of tri-state analogue outputs
0 Volts / 2.5 Volts / 5.0 volts @ 50 mA max
17.3
Maximum current rating
Maximum recommended current
< 300 A
Maximum recommended inrush current
< 1,000 A peak current
17.4
Temperatures
Maximum operating temperature
<= 85 deg C continuous internal temperature
Typical temperature rise over ambient
< 30 deg C @ 140 A; 30 minutes
17.5
Communication
PC Interface
CAN1..4
CAN ports
4, with full routing option between all ports
CAN protocol
2.0B
CAN baud rate (each CAN bus)
10 kbps to 1 Mbps, individually selectable
CAN1-CAN2 identifiers
11 bit or 29 bit identifiers
Motorola or Intel format
Maximum 64 individual numbers of identifiers
Bit wise operator
Row counts available
CAN3-CAN4 identifiers
11 bit or 29 bit identifiers
Motorola or Intel format
Maximum 5 individual numbers of identifiers
Bit wise operator
Row counts available
LIN bus
1; configurable as master or slave
Ethernet
1 @ 100 Mbit/s
Serial bus
RS232 serial link (for Supervisor).
17.6
Power Supply
Supply Voltage
6.0 to 30 Volts