“PFM” - PWM Frequency MSB
The frequency of the pulse width modulation channels can be exported.
The MSB channel can export values between 256..65,525 Hz.
Combining export of the LSB and MSB channels, frequencies between 0..65,535 Hz can be
exported. Channels can be arranged in Motorola format (MSB,LSB) or Intel format (LSB,MSB).
“PDC” - PWM Duty Cycle
The duty cycle of the pulse width modulation channels can be exported using a single byte,
showing values between 0..100%.
“CIL” - CAN Input LSB
Any CAN input channel can be exported on a CAN bus.
The LSB channel can export values between 0..255.
“CIM” - CAN Input MSB
Any CAN input channel can be exported on a CAN bus.
The MSB channel can export values between 256..65,535.
Combining export of the LSB and MSB channels, values between 0..65,535 can be exported.
These channels can be arranged in Motorola format (MSB,LSB) or Intel format (LSB,MSB).
“OFH” – Operational Fault Status
The MSB channels exports fault status values between 256…65535.
“CCL” – Over Current Low
Over current low byte.
“CCH” – Overcurrent High
Over current high byte.
“CTH” – Thermal Status
Counts thermal faults caused by output driver chip exceeding upper temperature threshold.
“CCS” – Overcurrent Soft
Counts faults caused by current draw exceeding the software fuse level threshold.
“CPK” – Peak Current Single
Peak current output on a single channel, expressed I A.
Copy From
It is possible to copy the settings from one address to another address.
Open the CAN address to configure.
From the drop down menu select the address to copy, then click the COPY button.
Save
Click on SAVE to save the CAN address changes.
Delete
Click on DELETE to clear a CAN address.